Not sure if the devices you have chosen are suitable? Click here and fill out the form, and our advisor will prepare an offer tailored to your requirements.
Roger MCT68ME Time Attendance System External/Internal.
- Poland free ship
Do you represent a budgetary unit?
Check out the deferred payment option.
Related products
Product Description
Main features:
- Access control set to support 1 passage in RACS 5 ST system.
- One login point
- Reader power supply from control panel, emergency power supply from battery
- User recognition via PIN codes and/or proximity cards of 13.56 MHz MIFARE® Ultralight/Classic standard and EM125kHz (UNIQUE) standard
- External/internal reader application
- Includes 5 key fobs
- Support for up to three NO/NC inputs
- Keypad with adjustable backlighting level
- Standalone operation of the set
T&A time registration:
Our set will allow you to manage working time more easily, accurately account for it and reduce costs. Effectively implemented working time registration supports the efficiency of the company. Time registration is based on specialized software for analyzing, recording and accounting of working time - RCP Master - and on RCP terminals designed for registration of RCP events. In addition, registration of working time, i.e. registration of RCP events, can be implemented from the level of the RACS access control system and then exported to the RCP Master software. What's more, the registration of working time realized from the level of VISO and RCP Master 4 programs enables the exchange of data between the programs without the participation of the operator, creating an integrated access control and working time registration system.
MC16-PAC-ST-1 transition access controller:
- Access control set for operating 1 passage in RACS 5 ST system
- two-way passage control
- support for MCT series readers (16 readers)
- support for PRT series readers (interface for 4 readers)
- support for readers with Wiegand interface (4 readers)
- support for readers with OSDP interface (16 readers, MCI-3 interface required)
- power supply output 0.2 A
- power supply output 1.0 A
- battery charging 0.3 A
- deep discharge protection
- 24 VDC/2.2 A power supply
- tamper switch
- space for 7 Ah battery
- dimensions: 250.0 x 250.0 x 80.0 mm (H x W x D)
Access control set designed to operate one passage in RACS 5 v2 system in ST version. The set enables operation of one two-way passage using RS485 readers (MCT series readers and OSR series readers with OSDP protocol), RACS CLK/DTA (PRT series readers) or readers with Wiegand interface. The readers and the lock are powered from power outputs located on the controller, which can supply 0.2 A and 1.0 A, respectively. The included power supply enables complete power supply of the controlled passage.
Dual access terminal MCT68ME-IO-I / MCT68ME-IO-O
The MCT68ME-IO-I is an identification terminal designed for use in the RACS 5 system. The readers act as a slave device to the access controller and cannot independently supervise the passage. The device can recognize users via PIN codes and/or proximity cards of the 13.56 MHz MIFARE® Ultralight/Classic standard and the EM125kHz (UNIQUE) standard. The MCT68MEIOI terminal supports reading the serial number (CSN) of an EM 125kHz or MIFARE proximity card. The MCT68ME-IOI is equipped with a practical 12-button numeric keypad. It makes it possible to open the door easily and quickly by entering the appropriate PIN code. An additional advantage of the reader is also 4 additional function keys to which virtually any function of the RACS 5 system can be assigned. The readers are equipped with a set of input and output lines, which in most cases allows complete operation of the passage without using inputs and outputs located on the access controller or expansion module. The MCT68ME-IO is mainly used as a time and attendance (T&A) terminal. The device is available in an indoor mounting version. The terminal has an RS485 interface through which it is connected to the communication bus of the MC16 controller, and is equipped with a four-line LCD display and a set of four programmable function keys.
- internal model: MCT68ME-IO-I
- dedicated to the RACS5 system
- card support:
- EM 125kHz UNIQUE(EM4100/4102)
- 13.56MHz ISO 14443A, MIFARE Ultralight/Classic
- terminal mode operation
- power supply: 12V DC
- three NO/NC inputs
- two transistor outputs with load capacity 1A/15V
- one relay output with load capacity 1.5A/30V
- readout range: up to 7 cm
- communication interface: RS485
- ingress protection class: IP41
- built-in keypad
- four programmable function keys
- built-in LCD display
- average current consumption: 100 mA
- three LED indicators
- defining the resting polarity of the output line
- signaling speaker with adjustable sound level
- tamper sensor (Tamper)
- detection of opening the housing and detachment from the ground
- firmware update via RS485
- keypad with adjustable backlighting level
- recommended as Time & Attendance terminal
- external model: MCT68ME-IO-O:
- waterproof class:IP54
- protective metal housing
- internal working conditions:
- working temperature: 5°C ~ 40°C
- humidity: 10% ~ 95%
- outdoor working conditions:
- operating temperature: -25°C ~ 60°C
- humidity: 10% ~ 95%
- weight:
- internal: approx. 410g
- outer: about 1150g
- dimensions (width/height/length):
- internal: 110x170x42mm
- external: 156x220x100mm
- warranty: 36 months
The kit includes:
♦ 1x MC16-PAC-ST-1-KIT contents (x1 MC16-PAC-ST-1 access controller, 1x LRS-50-24 - 24V DC/2.2A, 1x ME14-24V metal enclosure)
♦ 1x 12V/7AH VRLA battery
♦ 1x MCT68ME-IO-I/MCT68ME-IO-O indoor/outdoor reader
♦ 5x BS-12BK 13.56MHz RFID key fob with memory " key fob color may vary, subject to product availability."
Additional items, optional to be purchased in related products:
♦ roger interface RUD-3-DES " Required for configuration".
♦ RUD-6-LKY dongle " Required for configuration if paid license"
♦ roger RCPM4 25/50/250/500+ license "Depends on the number of users" After the above, please contact us for a customized quote
♦ MFC-2 proximity card
Technical specifications:
MC16-PAC-ST-1 Access Transition Controller: | |
Power supply voltage | Nominal 18VAC; acceptable 17-22VAC Nominal 12VDC, acceptable 10-15VDC Nominal 24VDC, acceptable 22-26VDC |
Current consumption (average) | 100mA at 18VAC (no load on AUX/TML outputs) |
Inputs | Eight parametric inputs (IN1-IN8) electrically connected internally to the plus of the power supply through a 5.6 kΩ resistor. For NO- and NC-type lines, a trigger threshold of about 3.5V |
Relay outputs | Two relay outputs with single NO/NC contacts, load capacity 30V/1.5A DC/AC |
Transistor outputs | Eight open collector type transistor outputs, load capacity 15V/150mA DC. Max total current flowing through the outputs at the same time 3A DC. |
Power supply outputs | Two power supply outputs: 12VDC/0.2A (TML) and 12VDC/1A (AUX) |
Distances | Up to 1200m for RS485 Up to 150m for RACS CLK/DTA and Wiegand |
Protection class | IP20 |
Environmental class | Class I |
Operating temperature | 5°C ~ 40°C |
Humidity | 10% ~ 95% (non-condensing) |
Weight | approx. 200g |
Dimensions (W/H/D) | 175x72x30mm |
ME-14-24V metal housing: | |
Power supply | LRS-50-24 24VDC/50W |
Nominal output current | 2,2A |
Tamper protection | Tamper switch NO/NC; 50mA/50VDC |
DIN rail | 1x 245mm |
Sheet | 0.8mm |
Color | Anthracite grey RAL 7016 |
Battery | Space for 7Ah battery |
Operating environment | Indoors; humidity up to 90%; ambient temperature from -10°C to +40°C |
Degree of protection IP | IP20 |
Weight | 2kg |
Dimensions (W/H/D) | 250x250x80mm |
Proximity reader Roger MCT68ME | |
Supply voltage | Nominal 12VDC, acceptable 10-15VDC |
Current consumption (average) | approx. 100mA |
Inputs | Three (IN1..IN3) two-state NO/NC input lines internally polarized to supply plus via 15kΩ resistor, switching threshold approx. 3.5V |
Relay outputs | Relay output (REL1) with single NO/NC contacts, load capacity 30V/1.5A DC/AC |
Transistor outputs | Two transistor outputs (IO1, IO2) open collector type, max load 15VDC/150mA |
Reading range | Up to 7 cm |
Tamper protection (TAMPER) | Isolated contacts 50mA/24V, shorted when enclosure is closed |
Cards | EM 125 kHz UNIQUE, compatible with EM4100/4102 and 13.56MHz compatible with ISO14443A and MIFARE |
Distances | Up to 1200m RS485 bus length between controller and reader |
Reading range | Up to 10 cm for EM125kHz cards Up to 7 cm for MIFARE cards |
Protection class | IP41 internal IP54-external |
Operating temperature | 5°C ~ 40°C internal -25°C ~ 60°C external |
Humidity | 10% ~ 95% |
Weight internal | approx. 410g |
External weight | approx. 1150g |
Internal dimensions (W/H/D) | 110x170x42mm |
External dimensions (W/H/D) | 156x220x100mm |
Similar products in this category
Quick online quote
Use our calculators for a quote. Fill in the form - Our consultants will prepare a dedicated offer
-
Quote form
Use our tool for a monitoring quote, provide basic information and receive the offer directly to your email
See
-
Quote form
Check how much the installation of an alarm costs, provide basic information and receive the offer directly to your email
See
-
Quote form
Quote an access control system in any facility. to specific zones and areas using any identification
See
-
Quote form
Get a quote for the costs of a double-leaf, sliding, garage gate for your building or property
See
Our recommendations
- City monitoring
- Home monitoring
- Estate monitoring
- Shop monitoring
- Pharmacy monitoring
- Parking monitoring
- Office monitoring
- School monitoring
- Warehouse monitoring
- Gas station monitoring
- Hard drive capacity calculator
- Lens focal length calculator
- Comprehensive expert support
- Efficient order processing
- Competitive prices, promotions, and discounts
- We care about consumer rights