Not sure if the devices you have chosen are suitable? Click here and fill out the form, and our advisor will prepare an offer tailored to your requirements.
Alarm control panel VERSA Plus
- Poland free ship
Do you represent a budgetary unit?
Check out the deferred payment option.
Product Description
The VERSA Plus control panel is designed to protect small and medium-sized premises. It makes it possible to create a wired or wireless system, as well as a hybrid system, combining both. It cooperates with ACU-120 and ACU-270 controllers, which offer excellent operating range of ABAX family devices - up to 500 m in an open area, which gives an area of 78.5 hectares.
VERSA Plus is the only solution that combines functionalities that were previously available only through the use of several separate devices. Its main board integrates modules: ETHM, GSM, INT-VG, INT-AV and PSTN dialer. Thanks to this, the VERSA Plus control panel allows communication through as many as three channels (Ethernet, PSTN, GSM/GPRS), ensuring effective information transfer.
- 4 programmable wired inputs (expandable to 30):
- support for NO and NC type detectors, as well as rolling shutter and vibration detectors
- support for EOL and 2EOL configurations
- Additional NC-type tamper input
- 5 programmable wired outputs (expandable to 12):
- 2 high-current outputs
- 2 low-current outputs of OC type
- 1 relay output
- 3 power outputs
- output for connecting an enclosure-mounted dedicated piezoelectric transducer (acoustic signaling)
- division of the system into 2 zones:
- possibility to assign a zone to two zones
- system control by means of:
- LCD or LED keypads
- VERSA-LCDM-WRL wireless keypads
- INT-TSG touch-screen keypads
- proximity cards
- remote controllers
- integrated PSTN module enabling:
- monitoring (SIA, ContactID, others)
- voice messaging (8 numbers, 16 messages)
- remote programming (300 bps modem) by means of the DLOADX program
- integrated GSM/GPRS module enabling:
- voice/SMS messaging
- SMS/GPRS monitoring
- handling of 2 SIM cards
- programming with the help of the DLOADX program
- integrated ETHM module enabling:
- e-mail messaging
- control by means of VERSA CONTROL application offering PUSH messaging
- monitoring to the station
- programming by means of DLOADX program
- built-in voice module:
- nearly 13 minutes for messages used in the voice menu
- more than 4 minutes for 16 messages for telephone messaging (a message can last up to 16 seconds)
- built-in USB-HID socket
- memory for 2047 events
- support for 30 users, each of which can be assigned:
- password
- proximity card
- remote control
- 4 timers enabling automatic:
- arming/disarming of zones
- output control (light on/off, garden sprinkler, etc.)
- detachable terminal strips
Technical specifications:
Voice messages | 16 |
Telephone notification numbers | 8 |
Load capacity of low-current programmable outputs | 50 / 12 VDC mA |
Event memory | 2047 |
Zones | 2 |
Timers | 4 |
Current capacity of the power supply | 2 A |
Housing dimensions | 266 x 286 x 100 mm |
Electronics board dimensions | 173 x 105 mm |
Operating temperature range | -10...+55 °C |
Supply voltage (±15%) | 18 V AC, 50-60 Hz |
Maximum humidity | 93±3% |
Battery current consumption - maximum | 340 mA |
Battery current consumption - standby | 180 mA |
Battery fault notification voltage (±10%) | 11 V |
Battery cut-off voltage (±10%) | 10,5 V |
Environmental class according to EN50130-5 | II |
Standby current consumption from 230 V mains | 120 mA |
Maximum current consumption from 230 V mains | 200 mA |
Power supply output voltage | 12 ±15% V DC |
Programmable wire inputs | 4 |
Maximum number of programmable inputs | 30 |
Programmable wire outputs | 5 |
Maximum number of programmable outputs | 12 |
Power supply outputs | 3 |
Communication buses | 1 |
Manipulators | up to 6 |
Grade of protection according to EN 50131 | Grade 2 |
AUX output load capacity | 500 mA / 12 V DC |
Recommended transformer | 40 VA |
Weight (including case and accessories) | 1250 g |
Users | 30 |
E-mail addresses for notification | 8 |
Text messages | 64 |
Load capacity of +VR output | 200 mA / 12 V DC |
KPD output load capacity | 500 mA / 12 V DC |
Load capacity of the programmable relay output | 1000 / 24 V DC mA |
Load capacity of high-current programmable outputs | 1100 / 12 VDC mA |
Output voltage range | 10.5 V...14 V DC |
Battery charging current | 800 mA |
"Source: Satel sp. z o.o., www.satel.pl".
Similar products in this category
Quick online quote
Use our calculators for a quote. Fill in the form - Our consultants will prepare a dedicated offer
-
Use our tool for a monitoring quote, provide basic information and receive the offer directly to your email
See
-
Check how much the installation of an alarm costs, provide basic information and receive the offer directly to your email
See
-
Quote an access control system in any facility. to specific zones and areas using any identification
See
-
Get a quote for the costs of a double-leaf, sliding, garage gate for your building or property
See
Our recommendations
- City monitoring
- Home monitoring
- Estate monitoring
- Shop monitoring
- Pharmacy monitoring
- Parking monitoring
- Office monitoring
- School monitoring
- Warehouse monitoring
- Gas station monitoring
- Hard drive capacity calculator
- Lens focal length calculator
- Comprehensive expert support
- Efficient order processing
- Competitive prices, promotions, and discounts
- We care about consumer rights